Precision CTC

 

 

PRECISION CLOSE TOLERANCE COOLING FOR COMPUTERS, TELECOMMUNICATIONS SWITCHING, MAINFRAME AND ALL IT APPLICATIONS

A leader in providing a proper climate for Telecommunications switching systems

Peace of Mind Protection

System Engineers, Office Managers and Data Processing Managers all recognize that telecommunications switching equipment and mainframe computer downtime can be devastating to a company's operation. Temperature, humidity and dust particles are all enemies of electronic components and must be properly controlled to prevent system failure. Lennox provides the solution with the CTC system which is available in air or water cooled and chilled water, and monitors your environment 24 hours a day, 365 days a year.

 Humidity Control

Wet bulb conditions in the space are controlled in two ways:
1    If the environment is over humidity, the Lennox CTC switches into the dehumidification mode. This is accomplished by the system changing blower speeds while continuing to cool. If the space temperature drops below the desired level, the Nichrome wire low watt density heaters are brought in, in stages to maintain the desired dry bulb.
2    If the environment is under humidity, the CTC will automatically switch into humidification mode, by bringing on the replaceable canister steam generator humidifier.

Optimum Performance

CTC is a microprocessor based upflow or downflow system that is capable of maintaining your space at ± 1.8, ±3% humidity

Complete Redundancy

Maintaining continuous conditioning is the critical element in protecting large computer systems. CTC is designed to provide cooling even if one component of the system should fail. Blowers evaporators and condenser sections are all microprocessor controlled, and the compressors are set up for lead/lag operation ensuring long equipment life.

Reliability & Peace of Mind

The CTC is designed to meet the most stringent acoustic requirements demanded for a computer room application. All cabinet panels are double wall, with heavy density insulation. Battery back up maintains systems set points in the event of power failure. Every CTC is equipped with primary and secondary drain pans. 

Configuration

Air and water-cooled DX models operates on R22 or R407C refrigerant. 
Up-flow and Down-flow models are available as per selection.

View Brochure for CTC2000 series
 