Model |
KM-9000a |
|
External measurements(W*D*H)
|
395*153*290 |
|
Water supply method
|
Direct connection to the tap
|
|
Water flow / pressure
|
1-3 Litres/min (3kg/cm2)
|
|
Weight(Kg)
|
5.4kgs |
|
Temperature to use
|
4-30 |
|
Electric power
|
AC110/240V |
|
Filter levels
|
3 levels |
|
First filtering method
|
Precipitation/Active carbon compound filters
|
|
Second |
Precipitation/Activated carbon/ Bio-ceramic
compound filters
0.01 microns |
|
Third |
Precipitation/Active carbon compound filters
(Alkaline smell
remover Patent No. 0539055)
|
|
Special features of the product
|
•*
Stable water supply through fitting super large filters.
•*
Easy to use by simple operation.
•*
Fitted with large LCD panel, it gives high recognition
ability and also it is easy to use because LCD color
changes according to the pH levels.
•*
To prevent over-electrolysis where the water quality
is not good, it is designed to be converted to the
lower level automatically if it overflows.
•*
The machine operates through the front water lever so
it is free from leakage and it stops its operation when
there is no water flow because it is designed to work
according to the amount of the water.
•*
Easy to use with LCD screen which displays ORP, pH,
and water levels.
•*
Using SPMS for the circuit and TROIDAL TRANS for
electrolysis, it can supply electric current more stable for
the necessary parts, instead of using conventional whole
TRANS or SPMS methods.
•*
It is able to supply the most suitable alkaline water
because it
can control the TRANS input electric power up to 10%.
•*
Disconnecting the electric power to the TRANS when the power
is on suspend mode, it can minimize overheating and
electricity consumption.
•*
We have chosen the acidic water control valve which is
controlled by the water pressure changes, so you can
always taste the best alkaline water. Usually the suitable
output water rate is 5:5.
|
|


|
Unique Advantage of McCoy Electrolyzer
As the first layer accumulation type electrode in Korea,
it can be used under all conditions. It can be optionally adjusted from
minimum 3 sheets to 20 sheets. Because it is easy to assemble and
disassemble the product, it is the only electrolyzer that cleaning and
regeneration can be performed on the electrolyzing plates. Depending on
its use, it can be changed into titanium or white gold electrode.
Because of its insert mold method, there is no leakage or
transformation.
Moreover, it can maintain horizontality and organization
through minimized gap between electrodes and individual sectional
diaphragm.
|

|
Generally, diaphragm is molded by insert mold method.
Therefore, it was hard to expect that diaphragm fulfills its role
because its organization is damaged by a compulsory pressure of molding.
However, the company's product adopts the method to insert diaphragm
after molding. Although other products have problems in maintaining the
horizontality, the company's product can maintain it by using separately
molded diaphragm. Therefore, the product is admitted as the one, whose
gap between pole plates are even and use is convenient.
|
|
By installing heat-sinks on both sides, it enable
electrolyzer to endure over-electrolysis caused by deterioration of
internal water quality and high heat caused by the failure of electric
unit, the product can discharge excessive heat generated inside to the
outside.
|

|
It is a
very special device which has never been installed on the basic ion
water purifier before. As a patent product which is only installed on
our KM-1006, KM-3000, and KM-9000 models, its foremost effect is to
remove the smell from the alkaline water and to improve the taste of the
water to the best. It is a very important device to prevent calcium
carbonate leakage and installed on our four models for the first time in
the world. During the washing or when the acidic water comes out to the
tap, the water bypasses this device, so you can feel more safe.
|


|
Generally, it is not possible to wash the inside of the
ion water purifiers. Our products have a function of selecting either
auto-cleaning or manual-cleaning, so there would be no alien substances
at the electrode board but there would be some calcium carbonate at the
septum. Usually, after using about a year in Korea, there should be some
alien substances throughout the inside of the water ways, but actually,
it has is very hard to clean and we usually leave them as it is. There
should be some kind of cleaning function because if it is left for a
long time, it would be smelly and not good for hygiene. Also if there
are any accumulated calcium carbonate, you can remove them as follows.
1.
Put the filter which is sold separately in the second shaft (Model
No, : ION CLINIC-mf-901)
2.
Choose the purifying function and let the water flow.
3.
Let it flow about 10 seconds and stop the water and leave it for
about 20~30minutes.
4.After
leaving it for 20 minutes, let the water flow again.
Check whether the water flows normally.
If you cannot get the normal result after ION CLINIC
filtering, you nee to wash the electrolysis cleaning
after disassembling.
|

|
The most vital part of an ion water purifier is the
amount of the water comes from the tap. If the water pressure is high,
there would be more alkaline water, but if it is very low, it might have
more acidic water. If this happens it is very hard to get good quality
water and sometimes the water flow backwards so the water might be mixed
and that’s why there should be a control valve. The ideal rate between
alkaline and acidic water is 5.5:4.5, but other companies’ products
don’t have this kind of valve and it may damage the purifier. Our
products are fitted with this control valve on the down part and it is
very easy to control and you can drink the most suitable ion water.
|

|
To get the most suitable working condition of this
purifier, we have included an incoming water control valve which can
control the amount of water coming in detail. When the water gets
through the purifier, check the LCD panel and make it not to go over 2
liters/min. |

|
Usually the electrolysis of the ion water purifier
chooses a trans or SMPS methods. In this case, the problem happens when
there is situation of overflow. Even though there are some devices that
can limit the supply of the power, the problem still happens when there
is a sudden overflow because of the quality and temperature of the
water, rather than consistent overflow. it affects the voltage which is
connected to the mycom and the machine can have problems. That’s why we
supply separate electric power. We have chosen SMPS method for the mycom
part and Troidal trans method for the electrolysis part, hence there is
no mutual interference or error when there are some overflows or any
voltage changes. Usually when you use Trans method, there always exists
the first electric power already which means there is continues power
flow and as the result, there are some chances of overheating and
microwaves. However, we have chosen an epoch making method to operate
the trans in a switching method by the relay when the electrolysis is in
working. Thus, if there is any overflow due to the water quality or
temperature, it will immediately measure the electric current and then
supply lower voltage. We have chosen the relay style power supply for
the first time in the world and it is patented. Also it is fitted with
rotary style switch to lower the electric power of the power supply
device about 10%, hence it is the only method for the best condition by
controlling voltage for about 10%.
|

|
Generally people tend to think that if there are large amount of
materials, it should be better even though that would depend on the
materials used. However a little differences happen when we purify
water. Now it is a common knowledge that it is better to put the
purifying materials in two tanks rather than put them all in one big
tank. It is because that when water get through the purifying materials
there will be some obstructions of the waterways, and if it is used for
a long time, the effectiveness will drop. The ion water purifiers we
make had been chosen from the method of purifying three times, the first
of its kind in this business field. The first filter eliminates alien
substances and organic compounds which are mixed in water, the second
filter uses materials which concentrates on eliminating organic
substances, and the third filter eliminates the carbonic acid ion and
inorganic substances which are made after the electrolysis. (Patent No.
539055) After the electrolysis, it removes the acidic materials, the
calcium carbonate and inorganic substance, but it still can have
electricity which doesn’t
happen in normal water. As the result of this, the power to be combined
together is very strong and some visible
crystals like white salt may appear. If this happens, it may cause some
unpleasant smell and if you keep the purified water in a container you
can see some sedimentations of calcium or sodium carbonates. But we have
chosen the world first method which eliminates all these kinds of
symptoms and this is the first ion water purifier device which is good
for human body.
|
|